Made-in-china.com

Made-in-Jiangsu.com

Home » Featured Products »

Temperature Sensor

» Jiangsu Product List

Product List

High Precision Ceramic Capacitive Pressure Sensor with an Ntc Thermistor for Energy Storage Liquid ...
Contact Now

17656.

High Precision Ceramic Capacitive Pressure Sensor with an Ntc Thermistor for Energy Storage Liquid ... Open Details in New Window [Apr 23, 2026]

Specification Operating Pressure: 0–10 barG (adjustable range available) Accuracy: ±1.0% FS @ 25°C Operating Temperature: -40°C to +135°C Media Temperature: -40°C to +135°C Storage Temperature: -40°C to +135°C Proof ...

Company: Saftty Electronic Technology Co., Limited.

HONEYWELL CITY TECHNOLOGY NO 5NF 1,000PPM 5SERIES SENSOR AF508-W0C
Contact Now

17657.

HONEYWELL CITY TECHNOLOGY NO 5NF 1,000PPM 5SERIES SENSOR AF508-W0C Open Details in New Window [Apr 14, 2026]

1. General Information Item Details Product Name 5NF CiTiceL® Nitric Oxide (NO) Gas Sensor Part Number (without bias board) AF508-W0C Part Number (with bias board) AF509-W0C (5BNF) Document ...

Company: BNSENS Co., Ltd.

HONEYWELL CITY TECHNOLOGY HCN 4HN 50PPM 4SERIES SENSOR AJ200-800
Contact Now

17658.

HONEYWELL CITY TECHNOLOGY HCN 4HN 50PPM 4SERIES SENSOR AJ200-800 Open Details in New Window [Apr 14, 2026]

1. General Information Item Details Product Name 4HN CiTiceL® Hydrogen Cyanide (HCN) Gas Sensor Part Number AJ200-800 Document Purpose Present performance specification of the 4HN CiTiceL Related ...

Company: BNSENS Co., Ltd.

Honeywell LEL 75M 100%LEL SENSOR MICROPEL Combustible Gas Sensor PM779-000
Contact Now

17659.

Honeywell LEL 75M 100%LEL SENSOR MICROPEL Combustible Gas Sensor PM779-000 Open Details in New Window [Apr 14, 2026]

1. General Information Item Details Product Name MICROpeL 75M Combustible Gas Sensor Part Number PM779-000 Document Purpose Present performance specification of the MICROpeL 75M Warranty 12 months from ...

Company: BNSENS Co., Ltd.

HONEYWELL CITY TECHNOLOGY O2 7OXV 25%VOL 7SERIES SENSOR AAV66-380
Contact Now

17660.

HONEYWELL CITY TECHNOLOGY O2 7OXV 25%VOL 7SERIES SENSOR AAV66-380 Open Details in New Window [Apr 12, 2026]

1. General Information Item Description Document Purpose Present performance specification of the 7OXV oxygen sensor Part Number AAV66-380 Related Documents Operating Principles (OP02), Product Safety ...

Company: BNSENS Co., Ltd.

HONEYWELL CITY TECHNOLOGY NO 3NFF 1,000PPM 3SERIES SENSOR AF006-J06
Contact Now

17661.

HONEYWELL CITY TECHNOLOGY NO 3NFF 1,000PPM 3SERIES SENSOR AF006-J06 Open Details in New Window [Apr 12, 2026]

1.General Information Item Description Document Purpose Present performance specification of the 3NFF Nitric Oxide gas sensor Related Documents Operating Principles (OP09), Product Safety Datasheet (PSDS ...

Company: BNSENS Co., Ltd.

HONEYWELL CO 1CO 1,000PPM 1SERIES SENSOR AB010-R01A
Contact Now

17662.

HONEYWELL CO 1CO 1,000PPM 1SERIES SENSOR AB010-R01A Open Details in New Window [Apr 11, 2026]

1. General Information Item Description Product Name 1CO Gas Sensor Gas Detected Carbon Monoxide (CO) Part Number AB010-RO1A Sensor Type Analogue gas sensor, low ...

Company: BNSENS Co., Ltd.

HONEYWELL CO 1CO 1,000PPM 1SERIES SENSOR AB010-R01A-CIT
Contact Now

17663.

HONEYWELL CO 1CO 1,000PPM 1SERIES SENSOR AB010-R01A-CIT Open Details in New Window [Apr 11, 2026]

1. General Information Item Description Product Name 1CO Gas Sensor Gas Detected Carbon Monoxide (CO) Part Number AB010-RO1A-CIT Sensor Type Analogue gas sensor, low ...

Company: BNSENS Co., Ltd.

HONEYWELL H2S 1H2S 200PPM 1SERIES SENSOR AC400-R00A-HON
Contact Now

17664.

HONEYWELL H2S 1H2S 200PPM 1SERIES SENSOR AC400-R00A-HON Open Details in New Window [Apr 10, 2026]

Product Overview Item Details Gas Detected Hydrogen Sulfide (H2S) Sensor Type Analogue Gas Sensor Part Number AC400-R00A-CIT Technology Electrochemical Design Compact, low profile Expected Operating ...

Company: BNSENS Co., Ltd.

HONEYWELL H2S 1H2S 200PPM 1SERIES SENSOR AC400-R00A
Contact Now

17665.

HONEYWELL H2S 1H2S 200PPM 1SERIES SENSOR AC400-R00A Open Details in New Window [Apr 10, 2026]

Product Overview Item Details Gas Detected Hydrogen Sulfide (H2S) Sensor Type Analogue Gas Sensor Part Number AC400-R00A-CIT Technology Electrochemical Design Compact, low profile Expected Operating ...

Company: BNSENS Co., Ltd.

HONEYWELL CITY TECHNOLOGY FLAMMABLE GAS LEL 4P75C 100%LEL 4SERIES SENSOR PM483-000
Contact Now

17666.

HONEYWELL CITY TECHNOLOGY FLAMMABLE GAS LEL 4P75C 100%LEL 4SERIES SENSOR PM483-000 Open Details in New Window [Apr 09, 2026]

Document: 4P75C CiTipeL® Combustible Gas Sensor Part Number: PM483-000 The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture. Output ...

Company: BNSENS Co., Ltd.

Honeywell  LEL 75C 100%LEL BW MICROPEL Combustible Gas Sensor PM769-000-BW
Contact Now

17667.

Honeywell LEL 75C 100%LEL BW MICROPEL Combustible Gas Sensor PM769-000-BW Open Details in New Window [Apr 08, 2026]

MICROceL® and MICROpeL® are one of the smallest, most compact sensors offered by Honeywell. The range includes carbon monoxide, hydrogen sulphide and fully certified combustible gas sensors. FEATURES AND ...

Company: BNSENS Co., Ltd.

Honeywell Oxygen Sensor OOM202 E01-00-0047
Contact Now

17668.

Honeywell Oxygen Sensor OOM202 E01-00-0047 Open Details in New Window [Apr 06, 2026]

OOM202 GAS SENSOR Oxygen (O2) Gas Sensor - Honeywell EnviteC Series From Standard Sensors to Customized Sensors Experienced Honeywell engineers work closely with customers to analyze their requirements when ...

Company: BNSENS Co., Ltd.

Honeywell CITY TECHNOLOGY CO 1,000PPM 4SERIES SENSOR 2112B3001
Contact Now

17669.

Honeywell CITY TECHNOLOGY CO 1,000PPM 4SERIES SENSOR 2112B3001 Open Details in New Window [Apr 05, 2026]

ECO-SURE X Carbon Monoxide [CO] Gas Sensor Part Number: 2112B3001 Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles ...

Company: BNSENS Co., Ltd.

Honeywell H2S H2S(M) 100PPM 4SERIES SENSOR 2112B2024 0-100 ppm
Contact Now

17670.

Honeywell H2S H2S(M) 100PPM 4SERIES SENSOR 2112B2024 0-100 ppm Open Details in New Window [Apr 05, 2026]

SureCellTM - H2S (M) Operating Performance Operating Principle:3-electrode electrochemical Gas Detected:Hydrogen Sulphide Measurement Range:0-100 ppm Maximum Overload²:150 ppm Expected Operating Life:2 years ...

Company: BNSENS Co., Ltd.