Jiangsu Profile

Product List
170506. H20 Timber Beam with Plywood Slab Formwork System Concrete Formwork Column Wall Formwork
[Aug 05, 2026]
[Aug 05, 2026] Product Description Table formwork Table formwork is a kind of formwork that used for floor pouring , used widely in high-rise building , multi-level factory building , underground structure etc. During the ...
170507. Lianggong Prefabricated Slab Table Formwork
[Aug 05, 2026]
[Aug 05, 2026] Table Formwork Production Description Table formwork is a kind of formwork that used for floor pouring, widely used in high-rise building, multi- level factory building, underground structure etc. During the ...
170508. Wss Series Bimetallic Dial Thermometer Gauge -80c to +500c - 100mm 150mm Stainless Steel ...
[Aug 04, 2026]
[Aug 04, 2026] High-Performance Industrial Bimetallic Thermometer (WSS Series) Our high-performance bimetallic thermometer is engineered for durability, precision, and versatility in pipeline, vessel, and industrial processing ...
Company: Jiangsu Hualiu Instrument Co., Ltd.
170509. Laminate Flooring Click Profiling Cutters
[Jul 24, 2026]
[Jul 24, 2026] PCD diamond cutter for flooring click profiling machine This cutter blade is used on Double End Tenoner ( Click Profiling Machine) for producing flooring. We also help customer design most suitable click system, ...
Company: Romeroca Industry Co., Limited
170510. Excellent Adhesion High Flash Point High Solid High Gloss Alkyd Coatings
[Jul 22, 2026]
[Jul 22, 2026] Construction Instructions 1. Use power tools or hand tools to stir thoroughly. Apply at 5 ° C to 40°C. 2. Application methods: airless spray, air spray, brush, roll. 3. Diluent: Exempted solvent, with an addition ratio ...
170511. Anti Rust High Flash Point High Solid High Gloss Alkyd Industrial Coating
[Jul 22, 2026]
[Jul 22, 2026] Construction Instructions 1. Use power tools or hand tools to stir thoroughly. Apply at 5 ° C to 40°C. 2. Application methods: airless spray, air spray, brush, roll. 3. Diluent: Exempted solvent, with an addition ratio ...
170512. High Flash Alkyd Industrial Coating for Steel Structure Anti-Rust Protection
[Jul 22, 2026]
[Jul 22, 2026] Product Description Item Valuve Theoretical usage 5.5 m²/kg (at 50 µm dry film, excluding loss) Specific gravity ≈1.40 Drying time (25°C) Touch dry ≤2 h, Hard dry ≤24 h Flash point 65°C Application methods Spray, brush, ...
170513. Fast Dry High Solid Alkyd Industrial Coating Good Adhesion High Coverage
[Jul 22, 2026]
[Jul 22, 2026] Product Description Item Valuve Theoretical usage 5.5 m²/kg (at 50 µm dry film, excluding loss) Specific gravity ≈1.40 Drying time (25°C) Touch dry ≤2 h, Hard dry ≤24 h Flash point 65°C Application methods Spray, brush, ...
170514. Heavy Duty Alkyd Industrial Coating High Flash Point High Gloss High Solids
[Jul 22, 2026]
[Jul 22, 2026] Construction Instructions 1. Use power tools or hand tools to stir thoroughly. Apply at 5 ° C to 40°C. 2. Application methods: airless spray, air spray, brush, roll. 3. Diluent: Exempted solvent, with an addition ratio ...
170515. High Solid Alkyd Industrial Coating Stable Performance Long Shelf Life
[Jul 22, 2026]
[Jul 22, 2026] Product Description Item Valuve Theoretical usage 5.5 m²/kg (at 50 µm dry film, excluding loss) Specific gravity ≈1.40 Drying time (25°C) Touch dry ≤2 h, Hard dry ≤24 h Flash point 65°C Application methods Spray, brush, ...
170516. High Flash Alkyd Industrial Coating for Bridge and Construction
[Jul 22, 2026]
[Jul 22, 2026] Product Description Item Valuve Theoretical usage 5.5 m²/kg (at 50 µm dry film, excluding loss) Specific gravity ≈1.40 Drying time (25°C) Touch dry ≤2 h, Hard dry ≤24 h Flash point 65°C Application methods Spray, brush, ...
170517. High Flash Alkyd Industrial Coating for Industrial Steel and Machinery
[Jul 22, 2026]
[Jul 22, 2026] Product Description Item Valuve Theoretical usage 5.5 m²/kg (at 50 µm dry film, excluding loss) Specific gravity ≈1.40 Drying time (25°C) Touch dry ≤2 h, Hard dry ≤24 h Flash point 65°C Application methods Spray, brush, ...
170518. Low Voc Alkyd Industrial Coating for Metal Equipment and Tank
[Jul 22, 2026]
[Jul 22, 2026] Product Description Item Valuve Theoretical usage 5.5 m²/kg (at 50 µm dry film, excluding loss) Specific gravity ≈1.40 Drying time (25°C) Touch dry ≤2 h, Hard dry ≤24 h Flash point 65°C Application methods Spray, brush, ...
170519. High Solid Low Voc Alkyd Anti-Corrosion Industrial Coating for Metal Structures
[Jul 22, 2026]
[Jul 22, 2026] Product Description Item Valuve Theoretical usage 5.5 m²/kg (at 50 µm dry film, excluding loss) Specific gravity ≈1.40 Drying time (25°C) Touch dry ≤2 h, Hard dry ≤24 h Flash point 65°C Application methods Spray, brush, ...
170520. High Performance High Flash Point High Solid High Gloss Alkyd Industry Coating
[Jul 22, 2026]
[Jul 22, 2026] Construction Instructions 1. Use power tools or hand tools to stir thoroughly. Apply at 5 ° C to 40°C. 2. Application methods: airless spray, air spray, brush, roll. 3. Diluent: Exempted solvent, with an addition ratio ...



















