Made-in-china.com

Made-in-Jiangsu.com

Home » Featured Products »

Semiconductor

» Jiangsu Product List

Product List

Wireless Dynamometer and Wireless Display Load Cell
Contact Now

5626.

Wireless Dynamometer and Wireless Display Load Cell Open Details in New Window [Jul 11, 2025]

Wireless Dynamometer and Wireless Display Load Cell 1.Product Description Main Technical Data: Display: 25mm (1'') 5digits LCD Power On Zero Range: 20% F. S. Manual Zero Range: 4% F. S. Tare Range: 20% F. ...

Company: Zhenjiang Matchau Marine Equipment Co., Ltd.

UL2808 Flex Current Sensor Cts 150A 0.33V
Contact Now

5627.

UL2808 Flex Current Sensor Cts 150A 0.33V Open Details in New Window [Jun 09, 2025]

UL2808 Flex Current Sensor Cts 150A 0.33V SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Xh-Sct-S24 Split Core Current Transformer Cts 150A 0.33V
Contact Now

5628.

Xh-Sct-S24 Split Core Current Transformer Cts 150A 0.33V Open Details in New Window [Jun 09, 2025]

XH-SCT-S24 Split Core Current Transformer Cts 150A 0.33V SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Xh-Sct-S24 Split Core Current Transformer Solar Cts 100A 50mA
Contact Now

5629.

Xh-Sct-S24 Split Core Current Transformer Solar Cts 100A 50mA Open Details in New Window [Jun 09, 2025]

XH-SCT-S24 Split Core Current Transformer Solar Cts 100A 50mA SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Xh-Sct-S24 Slim Clip-on Cts Current Transformer 70A 0.33V
Contact Now

5630.

Xh-Sct-S24 Slim Clip-on Cts Current Transformer 70A 0.33V Open Details in New Window [Jun 09, 2025]

XH-SCT-S24 Slim Clip-on CTs Current Transformer 70A 0.33V SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Xh-Sct-S24 Slim Clip-on Cts Split Core Current Sensor 100A 100mA
Contact Now

5631.

Xh-Sct-S24 Slim Clip-on Cts Split Core Current Sensor 100A 100mA Open Details in New Window [Jun 09, 2025]

XH-SCT-S24 Slim Clip-On CTs Split Core Current Sensor 100A 100mA SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Xh-Sct-S24 Clip on Current Transformer Cts
Contact Now

5632.

Xh-Sct-S24 Clip on Current Transformer Cts Open Details in New Window [Jun 09, 2025]

XH-SCT-S24 Clip on Current Transformer CTs SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Flex Sensors Clamp Current Transformer for Monitoring Energy and Solar
Contact Now

5633.

Flex Sensors Clamp Current Transformer for Monitoring Energy and Solar Open Details in New Window [Jun 09, 2025]

Flex Sensors Clamp Current Transformer For Monitoring Energy And Solar SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Clamp Current Transformer Cts for Home Energy Monitoring
Contact Now

5634.

Clamp Current Transformer Cts for Home Energy Monitoring Open Details in New Window [Jun 09, 2025]

Clamp Current Transformer CTs For Home Energy Monitoring SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Clamp Current Sensor 100A 0.33V
Contact Now

5635.

Clamp Current Sensor 100A 0.33V Open Details in New Window [Jun 09, 2025]

Clamp Current Sensor 100A 0.33V SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Split Core Current Sensor Cts 250A 0.33V
Contact Now

5636.

Split Core Current Sensor Cts 250A 0.33V Open Details in New Window [Jun 09, 2025]

Split Core Current Sensor CTs 250A 0.33V SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Xh-Sct-S24 Clamp Current Sensor Cts 300A 100mA
Contact Now

5637.

Xh-Sct-S24 Clamp Current Sensor Cts 300A 100mA Open Details in New Window [Jun 09, 2025]

XH-SCT-S24 Clamp Current Sensor CTs 300A 100mA SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

UL2808 Split Core Current Sensor Cts 70A 0.33V
Contact Now

5638.

UL2808 Split Core Current Sensor Cts 70A 0.33V Open Details in New Window [Jun 09, 2025]

UL2808 Split Core Current Sensor Cts 70A 0.33V SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

UL2808 Split Core Current Transformer Cts 120A 40mA
Contact Now

5639.

UL2808 Split Core Current Transformer Cts 120A 40mA Open Details in New Window [Jun 09, 2025]

UL2808 Split Core Current Transformer Cts 120A 40mA SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.

Clamp CT Current Sensor Solar CT
Contact Now

5640.

Clamp CT Current Sensor Solar CT Open Details in New Window [Jun 09, 2025]

Clamp CT Current Sensor Solar CT SPECIFICATIONS: 1,Rated Voltage:0.66KV 2,Insulation Voltage:5KV 3,Rated Frequency:50HZ or 60HZ 4,Operating Temperature:-15ºC to 60ºC 5,Flame ...

Company: Jiangyin Spark Electronic Technology Co., Ltd.