Jiangsu Profile

Product List
886. Chb25sm15D Series Current Transducer Closed Loop Device Based on The Measuring Principle
[Jul 24, 2026]
[Jul 24, 2026] Advantages The CHB25SM15D series current transducer is a closed loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate ...
Company: Cheemi Technology Co., Ltd.
887. High Precision Hall Type Effect Current Sensor for New Energy Combiner Box Measurement
[Jul 13, 2026]
[Jul 13, 2026] Advantages Feature * Closed- loop (compensated) current transducer * Supply voltage: DC +5.0V * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and ...
Company: Cheemi Technology Co., Ltd.
888. Current Mode Voltage Sensor for Accurate Electrical Measurements
[Sep 23, 2026]
[Sep 23, 2026] Advantages Feature * It is a current mode voltage sensor, based on the principle of the based on fluxgate principle. * Electrostatic shield between primary and secondary circuit * It provides accurate electronic ...
Company: Cheemi Technology Co., Ltd.
889. High Voltage 24kv Indoor Current Transformer for Switchgear
[Sep 10, 2026]
[Sep 10, 2026] Product Description Main Product Company Profile Nantong Saler Electric Co., Ltd. Our Journey Founded in 2007 as Shanghai Saler Electric in Songjiang, Shanghai, we have dedicated over a decade to the electrical ...
Company: Nantong Saler Electric Co., Ltd.
890. Jdzxw-35kv Outdoor Single-Phase Epoxy Resin Cast Voltage Transformer
[Sep 10, 2026]
[Sep 10, 2026] Product Description Type Limit output Rated insulating level JDZXW-35W2 600 40.5/95/200 JDZXFW-35W2 Main Product Company Profile Nantong Saler Electric Co., Ltd. Our Journey Founded in 2007 as Shanghai Saler Electric in ...
Company: Nantong Saler Electric Co., Ltd.
891. Jdz9-35kv Single-Phase Epoxy Resin Cast Indoor Voltage Transformer
[Sep 10, 2026]
[Sep 10, 2026] Product Description Type Rated Voltage ratio(kV) Accuracy classes combination Rated secondary output(VA) Limit output Raten insulating level JDZ9-27.5 27.5/0.1 0.2/0.5 50,100 1000 31.5/95/185 JDZ9-35 35/0.1 0.2/0.4/1.0 ...
Company: Nantong Saler Electric Co., Ltd.
892. High Precision 35kv Indoor Voltage Transformer for Power Distribution Systems
[Sep 10, 2026]
[Sep 10, 2026] Product Description Type Rated Voltage ratio(kV) Accuracy classes combination Rated secondary output(VA) Limit output Raten insulating level JDZ9-27.5 27.5/0.1 0.2/0.5 50,100 1000 31.5/95/185 JDZ9-35 35/0.1 0.2/0.4/1.0 ...
Company: Nantong Saler Electric Co., Ltd.
893. 35kv Outdoor Potential Transformer for High-Voltage Power Substations
[Sep 10, 2026]
[Sep 10, 2026] Product Description Type Limit output Rated insulating level JDZXW-35W2 600 40.5/95/200 JDZXFW-35W2 Main Product Company Profile Nantong Saler Electric Co., Ltd. Our Journey Founded in 2007 as Shanghai Saler Electric in ...
Company: Nantong Saler Electric Co., Ltd.
894. Indoor Single-Phase Fully Enclosed Epoxy Resin Casting Voltage Transformer
[Sep 10, 2026]
[Sep 10, 2026] Product Description Technical parameters as follows Rated Insulation Level Load Power Factor Pollution Class Product Standard 12/42/75 kV (10kV) cos = 0.8 (lag) Class II GB 20840.3-2013 IEC 61869-3 Type Rated voltage ...
Company: Nantong Saler Electric Co., Ltd.
895. High Voltage 35kv Indoor Epoxy Resin Current Transformer
[Sep 10, 2026]
[Sep 10, 2026] Product Description Outline Drawing Technical Data Parameter Specification Rated insulation level 40.5/95/185kV Rated secondary current 5A or 1A The load power factor cos phi=0.8 (lag) Product standard GB20840.2-2014 ...
Company: Nantong Saler Electric Co., Ltd.
896. Precision Indoor Current Transformer for Epoxy Resin Casting
[Sep 10, 2026]
[Sep 10, 2026] Product Description Outline Drawing Technical Data Parameter Specification Rated insulation level 40.5 / 95 / 185 kV Rated secondary current 5A or 1A The load power factor cos phi = 0.8 (lag) Product standard ...
Company: Nantong Saler Electric Co., Ltd.
897. Advanced Dual Power Relay Protection System for Current Transformers Sensor
[Jul 04, 2026]
[Jul 04, 2026] Principle CHK_BS12D4H series Hall Effect Open Loop Current Sensor is a current measurement device which develops on base of the hall effect principle, wherein a Hall-effect device (HED) produces an output voltage ...
Company: Cheemi Technology Co., Ltd.
898. Reliable Dual Power Supply for Current Transformer Relay Sensors
[Jul 04, 2026]
[Jul 04, 2026] Principle CHK_BS12D4H series Hall Effect Open Loop Current Sensor is a current measurement device which develops on base of the hall effect principle, wherein a Hall-effect device (HED) produces an output voltage ...
Company: Cheemi Technology Co., Ltd.
899. Dual Power Supply for Relay Protection and Hall Effect Sensor
[Jul 04, 2026]
[Jul 04, 2026] Principle CHK_BS12D4H series Hall Effect Open Loop Current Sensor is a current measurement device which develops on base of the hall effect principle, wherein a Hall-effect device (HED) produces an output voltage ...
Company: Cheemi Technology Co., Ltd.
900. Dual Power Supply for Relay Protection and VFD Sensors
[Jul 04, 2026]
[Jul 04, 2026] Principle CHK_BS12D4H series Hall Effect Open Loop Current Sensor is a current measurement device which develops on base of the hall effect principle, wherein a Hall-effect device (HED) produces an output voltage ...
Company: Cheemi Technology Co., Ltd.



















