Jiangsu Profile

Product List
7531. DN15-D25 Fully Automatic Heat Meter Test Bench (Piston Method+Mass Method)
[May 27, 2026]
[May 27, 2026] Specification Heat Meter Calibration Device, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7532. DN15-D25 Fully Automatic Heat Meter Test Bench (Mass Method+Standard Meter Method)
[May 27, 2026]
[May 27, 2026] Specification Heat Meter Calibration Device, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7533. DN15-D25 Fully Automatic Heat Meter Test Bench (Standard Meter Method)
[May 27, 2026]
[May 27, 2026] Specification Heat Meter Calibration Device, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7534. DN15-D25 Fully Automatic Heat Meter Test Bench (Mass Method)
[May 27, 2026]
[May 27, 2026] Specification Heat Meter Calibration Device, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7535. DN50-D200 Fully Automatic Water Meter Test Bench (Rotary type - Volumetric Method)
[May 27, 2026]
[May 27, 2026] Specification Water Meter Test Bench, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7536. DN50-D200 Fully Automatic Water Meter Test Bench (Tube-Replacement-Volumetric Method)
[May 27, 2026]
[May 27, 2026] Specification Water Meter Test Bench, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7537. DN50-D200 Fully Automatic Water Meter Test Bench (Flat Layout Type - Volumetric Method)
[May 27, 2026]
[May 27, 2026] Specification Water Meter Test Bench, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7538. DN50-D200 Fully Automatic Water Meter Test Bench (Tube-Replacement-Volumetric Method+Standard Meter ...
[May 27, 2026]
[May 27, 2026] Specification Water Meter Test Bench, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7539. DN50-D200 Fully Automatic Water Meter Test Bench (Tube-Replacement-Mass Method+Standard Meter ...
[May 27, 2026]
[May 27, 2026] Specification Water Meter Test Bench, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7540. DN50-D200 Fully Automatic Water Meter Test Bench (Rotary type - Mass Method)
[May 27, 2026]
[May 27, 2026] Specification Water Meter Test Bench, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7541. DN50-D200 Fully Automatic Water Meter Test Bench (Tube-Replacement - Mass Method)
[May 27, 2026]
[May 27, 2026] Specification Water Meter Test Bench, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7542. DN50-D200 Fully Automatic Water Meter Test Bench (Rotary type-Mass Method+Standard Meter Method)
[May 27, 2026]
[May 27, 2026] Specification Water Meter Test Bench, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7543. Fully Automatic Water Meter Test Bench 15-50 (Volumetric Method+Standard Meter Method)
[May 27, 2026]
[May 27, 2026] Specification Water Meter Test Bench, Urel ≤ 0.2% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
7544. Posture Correction Vest Braces Corrector Waist Belt Back Support ISO Approved
[May 26, 2026]
[May 26, 2026] Posture Correction Vest Braces Corrector Waist Belt Back Support ISO Approved Product Description Feature Material Flax Place of Origin Jiangsu,China Model Number H-55 Applicable ...
7545. Double Person 2.0ATA Hbot Chamber Home Person Hyperbaric Chamber 20L Oxygen Pod
[May 21, 2026]
[May 21, 2026] Product Description Highlights at a glance High-Efficiency 2.0ATA Pressure: Reaches clinical-grade pressure to significantly increase dissolved oxygen in the blood, shortening recovery time. Premium Carbon ...



















