13681. B60h Yojo Gasket Plate Heat Exchanger HVAC Marine Heat Exchanger Gasket Plate
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) M6/B60B N(2.0+X) 320 140 920 640 The bottom of the center to ground level (mm) 140 MAX.LC (mm) 1200 Connection (mm) 50 Maximum flow (m3/h) 36 Design pressure ...
13682. B150b Industrial Stainless Steel Plate Heat Exchanger for Petrochemical
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) M15B/B150B N(2.5+X) 610 298 1815 1294 The bottom of the center to ground level (mm) 275 MAX.LC (mm) 3000 Connection (mm) 150 Maximum flow (m3/h) 360 Design ...
13683. B30b (M3) Gasket Plate Heat Exchanger
[Mar 08, 2022]
[Mar 08, 2022] Model A (mm) B (mm) C (mm) D (mm) E (mm) MAX. LC (mm) Connection (mm) Exchange area (m2) Max. Number of plates Max. volume flow (m3/h) Design ...
13684. M6/B60b Titanium Plate Heat Exchanger, Phe, Heat Exchanger
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) M6/B60B N(2.0+X) 320 140 920 640 The bottom of the center to ground level (mm) 140 MAX.LC (mm) 1200 Connection (mm) 50 Maximum flow (m3/h) 36 Design pressure ...
13685. Mx20/B250b Plate Heat Exchanger for HVAC and Steam Heating Water
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) MX20/MX25/B250B N(2.5+X) 920 439 2895 1939 The bottom of the center to ground level (mm) 435 MAX.LC (mm) 3000 Connection (mm) 250 Maximum flow (m3/h) 750 Design ...
13686. M15b/B150b Plate Heat Exchanger for HVAC and Steam Heating Water
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) M15B/B150B N(2.5+X) 610 298 1815 1294 The bottom of the center to ground level (mm) 275 MAX.LC (mm) 3000 Connection (mm) 150 Maximum flow (m3/h) 360 Design ...
13687. M6 Titanium Plate Heat Exchanger, Phe, Heat Exchanger
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) M6/B60B N(2.0+X) 320 140 920 640 The bottom of the center to ground level (mm) 140 MAX.LC (mm) 1200 Connection (mm) 50 Maximum flow (m3/h) 36 Design pressure ...
13688. Mx25/B250b Plate Heat Exchanger for HVAC and Steam Heating Water
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) MX20/MX25/B250B N(2.5+X) 920 439 2895 1939 The bottom of the center to ground level (mm) 435 MAX.LC (mm) 3000 Connection (mm) 250 Maximum flow (m3/h) 750 Design ...
13689. M15b Plate Heat Exchanger for HVAC and Steam Heating Water
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) M15B/B150B N(2.5+X) 610 298 1815 1294 The bottom of the center to ground level (mm) 275 MAX.LC (mm) 3000 Connection (mm) 150 Maximum flow (m3/h) 360 Design ...
13690. B60b Titanium Plate Heat Exchanger, Phe, Heat Exchanger
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) M6/B60B N(2.0+X) 320 140 920 640 The bottom of the center to ground level (mm) 140 MAX.LC (mm) 1200 Connection (mm) 50 Maximum flow (m3/h) 36 Design pressure ...
13691. Mx20 Plate Heat Exchanger for HVAC and Steam Heating Water
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) MX20/MX25/B250B N(2.5+X) 920 439 2895 1939 The bottom of the center to ground level (mm) 435 MAX.LC (mm) 3000 Connection (mm) 250 Maximum flow (m3/h) 750 Design ...
13692. B150b Plate Heat Exchanger for HVAC and Steam Heating Water
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) M15B/B150B N(2.5+X) 610 298 1815 1294 The bottom of the center to ground level (mm) 275 MAX.LC (mm) 3000 Connection (mm) 150 Maximum flow (m3/h) 360 Design ...
13693. Mx25 Plate Heat Exchanger for HVAC and Steam Heating Water
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) MX20/MX25/B250B N(2.5+X) 920 439 2895 1939 The bottom of the center to ground level (mm) 435 MAX.LC (mm) 3000 Connection (mm) 250 Maximum flow (m3/h) 750 Design ...
13694. M6m/B60h Industrial Stainless Steel Plate Heat Exchanger for Petrochemical
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) M6/B60B N(2.0+X) 320 140 920 640 The bottom of the center to ground level (mm) 140 MAX.LC (mm) 1200 Connection (mm) 50 Maximum flow (m3/h) 36 Design pressure ...
13695. B250b Plate Heat Exchanger for HVAC and Steam Heating Water
[Mar 08, 2022]
[Mar 08, 2022] Model A(mm) B(mm) C(mm) D(mm) E(mm) MX20/MX25/B250B N(2.5+X) 920 439 2895 1939 The bottom of the center to ground level (mm) 435 MAX.LC (mm) 3000 Connection (mm) 250 Maximum flow (m3/h) 750 Design ...