137521. 1kv 3150A En50386 LV Porcelain Transformer Bushing
[Nov 27, 2024]
[Nov 27, 2024] Product Parameters 1KV/1800A EN50386 Porcelain Transformer Bushing Rated Voltage: 1kV Maximum Voltage: 1.1kV Rated Current: 1800A Wet Power Frequency Voltage: 5kV Minmun Creepage Distance: 75mm As a standard ...
137522. 1kv 1800A En50386 Low Voltage Porcelain Transformer Bushing
[Nov 27, 2024]
[Nov 27, 2024] Product Parameters 1KV/1800A EN50386 Porcelain Transformer Bushing Rated Voltage: 1kV Maximum Voltage: 1.1kV Rated Current: 1800A Wet Power Frequency Voltage: 5kV Minmun Creepage Distance: 75mm As a standard ...
137523. Low Voltage 1kv/5000A DIN 42530 Porcelain Transformer Bushing
[Nov 27, 2024]
[Nov 27, 2024] Product Parameters 1KV/5000A DIN 42530 Porcelain Transformer Bushing Rated Voltage: 1kV Maximum Voltage: 1.1kV Rated Current: 5000A Wet Power Frequency Voltage: 5kV Minmun Creepage Distance: 85mm As a ...
137524. 52kv 3150A DIN Transformer Bushing
[Nov 25, 2024]
[Nov 25, 2024] Product Parameters 52KV/630A DIN Transformer Bushing Highest Voltage: 52kV Rated Lightning Impulse Withstand Voltage: 250kV Power Frequency Withstand Voltage: 110kV Rated Current: 3150A Creepage Distance: ...
137525. High Voltage 52kv 1250A DIN Transformer Bushing
[Nov 25, 2024]
[Nov 25, 2024] Product Parameters 52KV/630A DIN Transformer Bushing Highest Voltage: 52kV Rated Lightning Impulse Withstand Voltage: 250kV Power Frequency Withstand Voltage: 110kV Rated Current: 1250A Creepage Distance: ...
137526. High Voltage 52kv/630A DIN Transformer Bushing
[Nov 25, 2024]
[Nov 25, 2024] Product Parameters 52KV/630A DIN Transformer Bushing Highest Voltage: 52kV Rated Lightning Impulse Withstand Voltage: 250kV Power Frequency Withstand Voltage: 110kV Rated Current: 630A Creepage Distance: ...
137527. High Voltage 210kN Cap and Pin Type Toughened Glasss Insulator
[Nov 25, 2024]
[Nov 25, 2024] 210KN Toughened Glass Insulator Spacing: 170 mm Diameter: 280 mm Creepage Distance: 400 mm Coupling: 20A(R) Minimum Mechanical Failing Load: 210 kN Lightning Impulse Withstand Voltage: 110 kV Power Frequency ...
137528. Pad Mounted Transformer Use Epoxy Resin Bushing with Spade Terminal
[Nov 22, 2024]
[Nov 22, 2024] Product Description Tri-clamp Molded Bushings We offer both high voltage and low voltage bushings designed for use in pad or surface mounted transformers. The bushings insulate the current carrying conductor from the ...
137529. Transformer Component ANSI 1.2kv 30kv Bil Epoxy Resin Bushing
[Nov 22, 2024]
[Nov 22, 2024] Product Description Epoxy Resin Bushings We offer both high voltage and low voltage bushings designed for use in pad or surface mounted transformers. The bushings insulate the current carrying conductor from the tank ...
137530. ANSI 1.2kv Low Voltage Epoxy Resin Bushing for Pad Mounted Transformer
[Nov 22, 2024]
[Nov 22, 2024] Product Description Epoxy Resin Bushings We offer both high voltage and low voltage bushings designed for use in pad or surface mounted transformers. The bushings insulate the current carrying conductor from the tank ...
137531. Tin-Plated Terminal LV Epoxy Resin Bushing for Transformer
[Nov 22, 2024]
[Nov 22, 2024] Product Description Tri-clamp Molded Bushings We offer both high voltage and low voltage bushings designed for use in pad or surface mounted transformers. The bushings insulate the current carrying conductor from the ...
137532. ANSI 1.2kv 2200A Epoxy Resin Bushing for Pad Mounted Transformer
[Nov 22, 2024]
[Nov 22, 2024] Product Description Epoxy Resin Bushings We offer both high voltage and low voltage bushings designed for use in pad or surface mounted transformers. The bushings insulate the current carrying conductor from the tank ...
137533. 70kN Cap and Pin Type Toughened Glass Insulator for Transmission Line
[Nov 22, 2024]
[Nov 22, 2024] Characteristics of glass insulators Small size, light weight, zero-value self-breaking, and easy detection; high mechanical strength; good arc resistance; good self-cleaning performance and not easy to age. In ...
137534. 120kN Cap and Pin Anti-Fog Toughened Glass Insulator for Transmission Line
[Nov 22, 2024]
[Nov 22, 2024] 12OKN Toughened Glass Insulator Spacing: 127 mm Diameter: 380 mm Creepage Distance: 365 mm Coupling: 16A(R) Minimum Mechanical Failing Load: 120 kN Lightning Impulse Withstand Voltage: 90 kV Power Frequency Dry ...
137535. 40kN Cap and Pin Type Toughened Glass Insulator for Transmission Line
[Nov 22, 2024]
[Nov 22, 2024] Characteristics of glass insulators Small size, light weight, zero-value self-breaking, and easy detection; high mechanical strength; good arc resistance; good self-cleaning performance and not easy to age. In ...