4426. Z4112/12b 550W Bench Type Drilling Machine with 100mm Spindle Travel
[Feb 18, 2024]
[Feb 18, 2024] Model Z4112/12B Max. Drilling capacity 12mm Diameter of column 70mm Max.spindle travel 100mm Morse taper of spindle nose B16 Spindle speeds 480-800-1400-2440-4100 r/min Size of worktable 265x265 Size of ...
Company: Changzhou Lunyee Electromechanical Manufacturing Co., Ltd.
4427. Benchtop Type Pulley Drive Drill Press CE Qualified Chuck Bench Drill Press
[Feb 18, 2024]
[Feb 18, 2024] Model Z4112/12B Max. Drilling capacity 12mm Diameter of column 70mm Max.spindle travel 100mm Morse taper of spindle nose B16 Spindle speeds 480-800-1400-2440-4100 r/min Size of worktable 265x265 Size of ...
Company: Changzhou Lunyee Electromechanical Manufacturing Co., Ltd.
4428. Industrial Bench Drill Magnetic Drilling Machine Variable Speed Metal Manual
[Feb 18, 2024]
[Feb 18, 2024] Model Z4112/12B Max. Drilling capacity 12mm Diameter of column 70mm Max.spindle travel 100mm Morse taper of spindle nose B16 Spindle speeds 480-800-1400-2440-4100 r/min Size of worktable 265x265 Size of ...
Company: Changzhou Lunyee Electromechanical Manufacturing Co., Ltd.
4429. 550W High Precision Mini Bench Drill with ISO 9001 Certification
[Feb 18, 2024]
[Feb 18, 2024] Model Z4112/12B Max. Drilling capacity 12mm Diameter of column 70mm Max.spindle travel 100mm Morse taper of spindle nose B16 Spindle speeds 480-800-1400-2440-4100 r/min Size of worktable 265x265 Size of ...
Company: Changzhou Lunyee Electromechanical Manufacturing Co., Ltd.
4430. DN15-D100 Fully Automatic Water Flow Calibration Device (Mass method)
[Jun 04, 2026]
[Jun 04, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
4431. DN15-D100 Fully Automatic Water Flow Calibration Device (Volumetric method)
[Jun 04, 2026]
[Jun 04, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
4432. DN15-D100 Fully Automatic Water Flow Calibration Device (Mass Method+Standard Meter Method)
[Jun 04, 2026]
[Jun 04, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
4433. DN15-D100 Fully Automatic Water Flow Calibration Device (Standard Meter Method)
[Jun 04, 2026]
[Jun 04, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
4434. DN15-D100 Fully Automatic Water Flow Calibration Device (Volumetric Method+Standard Meter Method)
[Jun 04, 2026]
[Jun 04, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
4435. Water Flow Calibration Device 15-50 (Piston + Mass + Standard Meter Method)
[May 29, 2026]
[May 29, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
4436. Water Flow Calibration Device15-50 (Piston Method+Standard Meter Method)
[May 29, 2026]
[May 29, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
4437. Fully Automatic Water Flow Calibration Device 15-50 (Piston Method + Mass Method)
[May 29, 2026]
[May 29, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
4438. Fully Automatic Water Flow Calibration Device 15-50 (Volumetric Method+Standard Meter Method)
[May 29, 2026]
[May 29, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
4439. Fully Automatic Water Flow Calibration Device 15-50 (Mass Method+Standard Meter Method)
[May 29, 2026]
[May 29, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...
4440. Fully Automatic Water Flow Calibration Device 15-50 (Standard Meter Method)
[May 29, 2026]
[May 29, 2026] Specification Water Flow Calibration Device, Urel ≤ 0.05% (k=2) Flow Stability 1.0% for Start-Stop Method; 0.2% for Other Methods Calibration Medium Pure Tap Water Operating Humidity Humidity: ≤ 93% RH Operating Water ...