Jiangsu Profile

Product List
3076. Customized UHF So239 Female to UHF Female RF Coaxial Connector Adapter
[Apr 23, 2026]
[Apr 23, 2026] TYPE UHF products is one kind of video frequency coaxial connectors with screw coupling and adopt tooth of end gearing. Impedance is not strictly definited, but usually applied at the frequency of 500MHz. This products ...
3077. Audio CCTV RF Coaxial BNC Male Clamp Connector for Rg58 LMR195 Cable
[Apr 24, 2026]
[Apr 24, 2026] TYPE BNC is one kind of RF coaxial connectors using a bayonet type coupling mechanism. Characteristic impedance has two types:50 ohm and 75 ohm, They can be quick connect/disconnect, reliable lock etc. They are widely ...
3078. Metal Protective Dustproof Cap for N Type Female RF Coaxial Connector
[Apr 22, 2026]
[Apr 22, 2026] The dust cap is to protect connectors from dust particles and contaminates that can cause damages to equipments. The connector dust cap is based on the metric dimensions of the connector interface, to fix on ...
3079. Metal Protective Dustproof Cap for N Type Male RF Coaxial Connector
[Apr 22, 2026]
[Apr 22, 2026] The dust cap is to protect connectors from dust particles and contaminates that can cause damages to equipments. The connector dust cap is based on the metric dimensions of the connector interface, to fix on ...
3080. Reego Scb18 3150kVA 10kv/0.4kv Dry-Type Transformer for Super Computing Center
[Apr 01, 2026]
[Apr 01, 2026] Dry-type Silicon Steel Transformer Applications Dry-type silicon steel transformers are mainly applicable to high-rise residential areas in cities, commercial office buildings, hotels, outpatient buildings of hospitals, ...
3081. Reego 1600kVA 13.8kv/480V Low Loss Dry Transformer Explosion-Proof for Residential Area
[Apr 01, 2026]
[Apr 01, 2026] Dry-type Silicon Steel Transformer Applications Dry-type silicon steel transformers are mainly applicable to high-rise residential areas in cities, commercial office buildings, hotels, outpatient buildings of hospitals, ...
3082. Reego 3150kVA 35kv/400V Anti-Corrosion Dry-Type Transformer Explosion-Proof for Railway Station
[Apr 01, 2026]
[Apr 01, 2026] Dry-type Amorphous Alloy Transformer Applications Densely populated urban residential areas, high-rise buildings, commercial complexes, hospitals, schools, data centers, distribution rooms along subway lines, and small ...
3083. Reego 2000kVA 11kv/480V High Temperature Resistant Dry Transformer Fireproof for Data Center
[Apr 01, 2026]
[Apr 01, 2026] Dry-type Silicon Steel Transformer Applications Dry-type silicon steel transformers are mainly applicable to high-rise residential areas in cities, commercial office buildings, hotels, outpatient buildings of hospitals, ...
3084. Reego 2500kVA 11kv/400V Low Noise Moistureproof Dry-Type Transformer Fireproof for School Building
[Apr 01, 2026]
[Apr 01, 2026] Dry-type Amorphous Alloy Transformer Applications Densely populated urban residential areas, high-rise buildings, commercial complexes, hospitals, schools, data centers, distribution rooms along subway lines, and small ...
3085. Reego 4000kVA 35kv/400V Dry-Type Transformer Fireproof for Ai Data Center
[Apr 01, 2026]
[Apr 01, 2026] Dry-type Amorphous Alloy Transformer Applications Densely populated urban residential areas, high-rise buildings, commercial complexes, hospitals, schools, data centers, distribution rooms along subway lines, and small ...
3086. Reego Scb18 2500kVA 10kv/0.4kv Dry-Type Transformer for Ai Computing Center
[Apr 01, 2026]
[Apr 01, 2026] Dry-type Silicon Steel Transformer Applications Dry-type silicon steel transformers are mainly applicable to high-rise residential areas in cities, commercial office buildings, hotels, outpatient buildings of hospitals, ...
3087. Reego 220kv 300mva Two-Winding Main Transformer Low Loss for Substation
[Mar 31, 2026]
[Mar 31, 2026] S18-22 220kV Three-Phase Two-Winding Off-Circuit Tap-Changing Power Transformer Applications 1. Hub substations of the main power grid and regional key substations. 2. Step-up transformers in large and medium-sized ...
3088. Reego 220kv 180mva Two-Winding Main Transformer Low Loss for Substation
[Mar 31, 2026]
[Mar 31, 2026] S18-22 220kV Three-Phase Two-Winding Off-Circuit Tap-Changing Power Transformer Applications 1. Hub substations of the main power grid and regional key substations. 2. Step-up transformers in large and medium-sized ...
3089. Reego 220kv 240mva Two-Winding Main Transformer Low Loss for Substation
[Mar 31, 2026]
[Mar 31, 2026] S18-22 220kV Three-Phase Two-Winding Off-Circuit Tap-Changing Power Transformer Applications 1. Hub substations of the main power grid and regional key substations. 2. Step-up transformers in large and medium-sized ...
3090. Reego 220kv 150mva Two-Winding Main Transformer Low Loss for Substation
[Mar 31, 2026]
[Mar 31, 2026] S18-22 220kV Three-Phase Two-Winding Off-Circuit Tap-Changing Power Transformer Applications 1. Hub substations of the main power grid and regional key substations. 2. Step-up transformers in large and medium-sized ...